Dimension One Circulation Pump, Laing E10 – 01512-320E

$895.87

*PLEASE NOTE* This pump is not compatible as a replacement for a fountain circulation pump. This circ pump includes a flow switch. Not compatible with Arena or AFS. If replacing from non-E10 circ pump, please follow instructions that come with the pump as there are wiring differences.

The original red or blue pumps have been upgraded to the new all-black model which includes both dry run protection and an integrated flow switch.

This redesigned and upgraded 80 watt / 230 volt pump replaces your original 98w /115 volt version. Simply move a neutral wire from the circulation pump plug (where it attaches on the circuit board) and put it on line 2 of the incoming power, at the time of installation to accommodate the voltage increase. So easy we’ll even walk you through it on the phone!

Instructions:

To Make it 220V ready: Move White Wire (neutral) from P41 to P54

Where to connect pressure switch to circuit board: Connection P10 (Bottom, Right Corner)

Many low flow/heating problems can be corrected with a new circulation pump, so call us first to review troubleshooting tips before replacing other parts.